SEGUEIX-NOS!

No et perdis res de Macedònia, segueix-nos a:

i també a Musical.ly

@grupmacedoniaoficial


CONTRACTACIÓ 

 

macedonia@grupmacedonia.net

(+34) 639 129 327

Dani Coma

CONTACTE AMB EL GRUP

macedonia@grupmacedonia.net


refrigerator compressor ohm test
Lloc web del grup Macedònia, hi trobareu tota la informació del grup, dels discos, dels concerts i de totes les generacions de fruites des de 2002.
Macedònia, grup, fruites, barcelona, catalunya, posa'm un suc, sakam te, gira la fruita, bla bla bla, m'agrada, et toca a tu, els nens dels altres, el món és per als valents, flors, desperta, música, rock, nens, nenes, pinya, llimona, maduixa, mandarina, kiwi, laura, nina, alba, amanda, mariona, clàudia, aida, berta, èlia, laia, irene, sara, paula, maria, carlota, gina, carlota, noa, anna, mar, fruites, castellar del vallès,
1609
post-template-default,single,single-post,postid-1609,single-format-standard,ajax_leftright,page_not_loaded,,select-theme-ver-3.5.2,menu-animation-underline,side_area_uncovered,wpb-js-composer js-comp-ver-5.5.4,vc_responsive

refrigerator compressor ohm test

Find the fridge compressor and remove the plastic case that houses the starting circuitry. pin. William B. Lv 7. 0 0. iRomehony Start Relay Refrigerator PTC Ohm 3 Pin Replacement For Vissani Danby Compressor QP2-4.7 Ultra Durable 6750C-0004R Refrigerator Overload Protector Replacement Part by Blue Stars - Exact Fit For LG & Kenmore Refrigerators - Replaces 6750C-0005P This can be due to excessive loads, poor airflow or lack of superheat. The compressor is the heart of the refrigerator's hermetically sealed refrigerant system. Once the wires are disconnected, you can ohm out the wires, plug and compressor as they all require an inspection. To find out Lee decided to run his own test on three of the fridges that Magnum Motorhomes sell – the Dometic CRX50, our Vitrifrigo C51i and the Chinese DC-50. Test the refrigerator defrost heating element for continuity using a multimeter. If you do hear a humming noise, but the food in your fridge is warm, your compressor may be functioning improperly (or it may be a different issue causing the problem altogether). With the compressor being the most expensive component in the system, it is wise to be sure that it was bad before condemning it. Ensure to turn off the power source to keep yourself safe during the process. If necessary, turn on the meter volt AC and check it out. Therefore, when you remove the compressor leads (wires) from the plug to check resistance through the compressor windings, the pressure of the Freon can launch the plugs with as much as 20,000 pounds of force. This instructable shows how to test a PTC relay to determine whether it is… Find the PTC relay. If your ohm readings are above 30, it means that your compressor motor is likely faulty and you’ll need to get it replaced. Or, you need to figure out how to wire up a generic (Supco) start relay/overload combination. Check out our one-day technical class, You can use an ohm meter to test a capacitor. Find discounts and allowances on washing machines, kitchen stoves, refrigerators, and more. refrigerator clipart test clipart. Source(s): https://shorte.im/a95Cp. It then redirects the power to the compressor and fans to come back on when the defrost cycle is over. Could that be an issue. Sometimes the gap leaves blade does that broke away from the main control panel. Refrigerator Compressor Testing. Refrigerator Compressor Test. How to Test a Refrigerator Thermostat — A Quick Recap! Check the manufacturer's spec for what that exact resistance reading should be. 17.95 $ 17. A do-it-yourselfer can test and replace many of these refrigerator components. It's fairly easy to perform a continuity test on the fan to determine whether or not you need to replace it. Your refrigerator thermostat is the first thing you want to check when you notice a sudden temperature difference. Pack: 1. Refrigerator Compressor | Refrigerator Troubleshooting Diagram amperage when terminating its defrost cycle and entering the freeze In fact, the compressor might trip its thermo-overload at that: pin. How to Troubleshoot Fridge Compressors. If the resistances vary from each other by as much as a 1 ohm, the compressor will not run correctly. If the continuity test is negative the component has failed and will need to be replaced. Step 1 - Understand What and Where. Let’s say you’re gonna do some tests on your refrigerator compressor to see if it’s okay. With the compressor being the most expensive component in the system, it is wise to be sure that it was bad before condemning it. So you pull the relay cover off the compressor, remove the relay/overload and this is what you see. What ever works for you is suitable. Like a clock, this keeps the rhythm of defrosting and cooling going according to pre-set time intervals. Testing Refrigerator and Freezer Compressors. When this happens, the fault could be in the wiring, the control panel or the fan itself. So you pull the relay cover off the compressor, remove the relay/overload and this is what you see. The compressor on my Kenmore model 106.54682300 runs for 5 sec and shuts off, comes back on in 2 min and repeats. Part no: LSD013*SL. Compressor connection color Black(U)/Blue(V)/Yellow(W) Ambient operating temperature -5~43℃ Storage temperature -25~85℃ Max. So the readings I get are not 'so' off but there are a bit off. A shorted motor will read 0 ohms across windings, to ground, or both. This Independence Day, shop from a variety of home appliances for your friends and family. After all was said and done, it will cost me $348 for a service call which can only be done by their service techs. Find the fridge compressor and remove the plastic case that houses the starting circuitry. Part no: COMD. Here’s something else I get a lot of questions about: testing refrigerator and freezer compressors. A condition that occurs when a conductor of one of the parts of the motor windings. Make sure that it rests on the infinity. Approximately one in 20 HVAC technicians suffer injuries that could be prevented by taking the proper safety precautions. Now, with the meter on the low setting R X 1 scale you should get a low reading across the terminals. Or, you need to figure out how to wire up a generic (Supco) start relay/overload combination. . Testing Refrigerator and Freezer Compressors. The multitester should display a reading of zero ohms. DISCONTINUED. Set 03. Zero your counter. With the system pressure lowered, it is now safer to remove the plug and test the compressor terminals directly. Either memorize the wiring or take a few pictures just to be sure you know how to put it all back together when you're done. Taking the time to learn how to test a refrigerator start relay can help you find any problems, fix them, and ultimately save you the money you'd have to spend on a new one. You will need a good ohmmeter that can be measured with one ohms up to 20 kOhm. . This way, if something goes wrong you will destroy a tool, not your fingers. A fridge with a faulty PTC relay cannot start or continuously clicks on and off unable to start. refrigerator compressor ohm test. Refrigerator Compressor Relay Starter for QP2-15 QP2-12 Universal Type Three Inserts 15 Ohm Refrigerators Accessories. Continued from page 1. Could that be an issue. Save 10% on 2 select item(s) FREE Shipping on orders over $25 shipped by Amazon. Show/hide. In the below diagram I have shown an Analog multimeter set on the connectivity test, ohm test (resistance testing). use the OHM,s setting 2K a mid range or more reading is good . Show/hide. 1 decade ago. Note the resistance. Set 02. This Section "Refrigerator Parts-Compressor System Testing" is for Technicians It is not a complete service manual. Set 03. Finally, the resistance between run and start should be the sum of S to C and R to C. Remember, there should be a measurable resistance through each winding. View All Answers. It's an all-or-nothing test that tells you if the capacitor is dead, but it won't diagnose one that is still functioning weakly but about to stop working. This is done with the help of a small screws at the base of the arrow indicator. A refrigerator requires a compressor to keep the interior cold. For this reason, you should learn a systematic method of diagnostics compressor. refrigerator clipart test clipart. (0:23) - STEP 2: Remove lower front panel from cooler. This condition occurs when the winding insulation of the electric motor drive leakage of electricity began compressor body. Then touch the two probes together and turn selector switch in position X1000 scale. Before opening condensing unit turn off the electric power to the device. Grounded compressor (short circuit). Kenmore Elite79049. Blown fuses result. Purchase a new compressor motor if your ohm readings are high. Pack: 1. //-->. Refrigerator Overload Protector Testing Using Multi-meter Here I try to make you understood using a simple refrigerator overload protector testing troubleshooting diagram. There should be a measurable resistance through each set of wires. Make sure your meter is zero’d out and calibrated. “Testing is important to confirm proper operation of all three system prime movers — the compressor, the fan, and the blower,” said Jerry Edwards, manager, electric engineering and motor technology, Bristol Compressors Intl. Correct Answer. But if you want to check your compressor himself then this post is for you. A heating and air specialist may be able to repair the broken compressor motor instead of having to buy an entirely new compressor. If it is both, you will need to replace the compressor. In the case that any of the tests above fail, you need to check the compressor posts themselves. There are many ways to mark them as different colors tape, black bars electricians tape notch with the knife blade. Buyer Protection . View All Answers. No store found for that zipcode and search radius. You may occasionally hear this type of noise from the back of the refrigerator (starts about 15 seconds in): This is the sound of your compressor trying, but failing miserably, to start. When testing across the compressor terminals, first make sure all the terminals are bare, nothing connected to them and the terminals are not corroded. William B. Lv 7. Part no: SRF014. google_ad_height = 280; Read your repair manuals, service and parts updates/bulletins, and specific manufacturer's instructions. Sign in with the same credentials. How To Test the Compressor Relay. Next, locate the three wires that power up the compressor – the common, start and run winding – and remove the wires from the contactor and the capacitor. 2. A fridge with a faulty PTC relay cannot start or continuously clicks on and off unable to start. Remember proper lockout, tag out rules! In this post, I am telling you about some main and common reasons for compressor not working and about testing compressor methods. Modern refrigerators have a defrost function with a defrost timer, thermostat, heater, and drain, combined with an evaporator fan motor.You may need to test your defrost timer at some point. The resistance readings between the 3 pins are 1.1 Ohms (between the compressor pins that are ultimately connected to the line voltage), 18.8 Ohms, and 17.9 Ohms. In a vapour compression refrigeration system, a throttle valve is used in place of an expander because (A) It considerably reduces mass of the system (B) It improves the C.O.P., as the condenser is small (C) The positive work in isentropic expansion of liquid is very small (D) It leads to significant cost reduction. 1 decade ago. In order to determine the exact cause of a compressor malfunction, manufacturers say thorough and accurate diagnostics are a must. US $3.21-20%. Some also record and make calculations to help make the cycle more accurate. View details & Buy. Find the PTC relay. Have a LennoxPros.com account? Video explaining how to test the compressor if you have a refrigerator that is not getting cold. They add to a perfect 10, but I am not sure if starter coil resitance and the winding resitance should be that close. Want to learn more about dealing with compressors and other air conditioning and heat pump topics? Compressor not functioning after only 18 months. The ohms readings between the terminals are 4.7, 5.3 and 10. Absolutely pitiful product, Model LMXC23746S/00. How to Test a Refrigerator Relay Switch. Test dif [bar] [Max] 30 bar: Test HP [bar] [Max] 30 bar: Test LP [bar] [Max] 25 bar: Torque earth [Nm] 3 Nm: Torque power [Nm] 3 Nm: Total height [mm] 519 mm: Type: MT: Type designation: Compressor: Viscosity [cP] 32 cP: Winding resistance for three-phase compressors with identical windings [Ohm] 0.51 Ohm Sometimes when our refrigerator compressor stop working or not running a problem then we must call a professional to test the compressor or refrigerator. Make sure that the power is off. Faulty Start Relay or Capacitor . How to Test a PTC Relay / Fix a Fridge That Cannot Start / Clicking Fridge: A PTC relay is a device that is used when the fridge compressor motor starts. Carefully disconnect the wires with a pair of pliers, and then remove the relay by pulling it off of the prongs on the compressor. The lowest resistance will be found between the run(R) to common(C). Place one probe on any terminal and then touch the other probe to each of the other two terminals. [13] Then, use a multimeter to check the relay for open resistance. Account & Lists Account Returns & Orders. There's usually a diagram somewhere as well - make sure you can follow it and identify parts. In fact, this is one of the ways of checking an inverter compressor: making sure that all three windings have the exact same resistance. How to Test a PTC Relay / Fix a Fridge That Cannot Start / Clicking Fridge: A PTC relay is a device that is used when the fridge compressor motor starts. In fact, this is one of the ways of checking an inverter compressor: making sure that all three windings have the exact same resistance. It's fairly easy to perform a continuity test on the fan to determine whether or not you need to replace it. If it is both, you will need to replace the compressor. Set 01. Your refrigerator thermostat is the first thing you want to check when you notice a sudden temperature difference. It's not the easiest task for a do-it-yourselfer to complete, but with a little focus and determination, it can be done. You should have an infinite OL resistance to ground. The compressor is … Find the fridge compressor and remove the plastic case that houses the starting circuitry. Pack: 1. 95 19.94 $19.94. US $3.00. Check back soon. Learn to test the start relay of the compressor: 1. How to Test a Refrigerator Relay Switch. The internal overload is wired in series with both the start and run winding which prevents the compressor from coming on. Test the compressor motor for continuity using a multitester. So the readings I get are not 'so' off but there are a bit off. I had a look at the data sheet of the compressor (NJ2212GK) and the resistance rating for the start winding is 7.25 ohms, the rated resistance value for the run winding is 1.95 ohms. This refrigerator had the compressor replaced 4 months ago and then again, one month later.” Terrible product. I use an infrared temperature sensing gun for this. A shorted motor will read 0 ohms across windings, to ground, or both. You’re looking for readings in the k-ohms range. PTC Danfoss 103N0003 – 115V (originally white ceramic, top half looking rather brown now) plugs onto the compressor and applies 6.9 Ohms (cold) across the compressor pins that measure 17.9 Ohms. 5.0 (5) 13 Orders. Dec 21, 2017 - (0:07) Ohm Testing a Compressor (0:12) - STEP 1: Remove (4) 5/16" lower panel screws. Other basic parts of the cooling/defrosting system include switches, thermostats, heaters, condensers, and fans. The current drawn is about 17.6 amps, tag says max current is 6.5 amps. Refrigerator PTC Starter Relay 12 Ohm 3Pin & Compressor Overload Protector for Refrigerators … The fan should come on whenever the compressor cycles on. You may occasionally hear this type of noise from the back of the refrigerator (starts about 15 seconds in): This is the sound of your compressor trying, but failing miserably, to start. Correct Answer. Hi guys, just to give an update. There's usually a diagram somewhere as well - make sure you can follow it and identify parts. A refrigerator requires a compressor to keep the interior cold. To test the PTC relay in your refrigerator, unplug the fridge and remove the lower back panel so you can access the relay, which will look like a small black box with 2 or 3 wires running into it. Remember to exercise extreme caution because on a 90-degree day, the pressure in a de-energized R410A system can be approximately 275 psi and when a compressor has shorted out, the plug can overheat and become soft. If it doesn't, the refrigerator won't get cool enough to preserve your food. Set the multitester to the ohms setting X1. Test the refrigerator defrost heating element for continuity using a multimeter. 3. It then redirects the power to the compressor and fans to come back on when the defrost cycle is over. We’re dealing with electricity here; don’t mess around! Please send information on how to test the compressor using and ohm meter and amp meter. Set 01. Calling the service line is a joke. (adsbygoogle = window.adsbygoogle || []).push({}); Copyright @ 2009 - 2020, "www.ref-wiki.com". The resistance between start(S) to common(C) is typically three-to-five times higher than run to common winding. You will need a good ohmmeter that can be measured with one ohms up to 20 kOhm. Test the compressor relay for continuity using a multitester.Set the multitester to the ohms setting X1. For safety’s sake, the first thing you need to do is disconnect the power at the unit disconnect or breaker. Unlike a megger, a multimeter doesn't have enough volts to find shorts on mains equipment. WHIRLPOOL FRIDGE COMPRESSOR DRIP TRAY DISH**DISCONTINUED. Cart This fridge also features a building can dispenser inside the freezer compartment. Advanced AC & Heat Pump Diagnostics. After checking voltage, mark the wires connected to the terminals so that they can be returned to the same position when re-assembled. If you do hear a humming noise, but the food in your fridge is warm, your compressor may be functioning improperly (or it may be a different issue causing the problem altogether). Can't find what … Let’s say you’re gonna do some tests on your refrigerator compressor to see if it’s okay. Set 02. The landlord can do and less expensive, due to the fact that it will not be much use of techniques will give it. The unit's compressor system, which forces the coolant through the coil system, is driven by a capacitor-type motor. Always remember, safety first. The compressor is … With the relay upside down, place the probes into the terminals labeled "S" and "M". Here's the simple procedure I use whenever I run into one that’s ‘short-cycling’ (trying to start, clicking on/off every few seconds, or in some cases, every minute or two). In the case of single-phase units, the same locked rotor condition will be a witness, if the system has a start-up component. To open a factory. google_ad_width = 336; They are ideal if you need: + a silent compressor + a high pressure compressor + have little space and/or don't need a typical shop compressor Typical fridge compressors are 100 - 300 watt units, deliver 0.7 - 1 CFM of air and can reach pressures over 500 psi. google_ad_slot = "3099818450"; SALTON FRIDGE COMPRESSOR 1/12 HP R600. With the relay removed from the compressor, the resistance between the start winding and common is 3 ohms, between motor winding and common is 9 ohms … Continued from page 2. In this 6-minute video, Doug Smiley, Technical Training Manager, shows how to read ohms on a compressor. Multimeter allows to diagnose internal fault in the electrical equipment of the compressor. – Measure the sensor resistance. The compressor is the heart of the refrigerator's hermetically sealed refrigerant system. HQRP 4.7 Ohm 3-Pin Compressor PTC Starter/Start Relay and Overload Kit compatible with Compact Mini Fridges, Beer/Wine Refrigerators, Beverage & Wine/Beer coolers, Deep Freezers . RCA RFR321-FR320/8 IGLOO Mini Refrigerator Has the third-quietest refrigerator compressor. Disconnect the refrigerator As you are going to work in the rear part, for your protection, the appliance should not be energized. Ensure to turn off the power source to keep yourself safe during the process. Refrigerator Compressor Relay Starter for QP2-15 QP2-12 Universal Type Three Inserts 15 Ohm Refrigerators Accessories 5.0 Store: Alison living Store. Source(s): https://shorte.im/a95Cp. This procedure is used also in case, if the compressor is not running when called to do so. Not only can that damage the unit, but it can send the terminal through anything that is in front of it – be that your hand or any other body part.   Exclusive promotions Here’s something else I get a lot of questions about: testing refrigerator and freezer compressors. Find the PTC relay. Compressors For Refrigerator & Freezer. Remember, always keep to one side of the unit when working on single-phase compressors! FITS MODELS: SAL120M, SAL120W. The fan should come on whenever the compressor cycles on. It is possible that you could think of neutral leg 120 volt circuit, as grounded compressor. Either memorize the wiring or take a few pictures just to be sure you know how to put it all back together when you're done. Refrigerator Compressor | Refrigerator Troubleshooting Diagram testing-compressors: pin. Compressor won't run or it is "clicking' on and off: This normally could be a bad start relay and over load for the compressor, dirty condenser coils need cleaning, condenser fan motor is not running or the compressor itself. US $9.33 . Some also record and make calculations to help make the cycle more accurate. Not a member? You should have an infinite OL resistance to ground. The needle should distract zero ohms. Product Sold Out. Take all precautions when testing or working on any electrical equipment. Product Sold Out. In a vapour compression refrigeration system, a throttle valve is used in place of an expander because (A) It considerably reduces mass of the system (B) It improves the C.O.P., as the condenser is small (C) The positive work in isentropic expansion of liquid is very small (D) It leads to significant cost reduction. .and more! For Haier Refrigerator Starter TY-QZ-108 Protector B52-120 Compressor Relay Accessories with 4.5UF Capacitor. Get shopping advice from experts, friends and the community! Compressor won't run or it is "clicking' on and off: This normally could be a bad start relay and over load for the compressor, dirty condenser coils need cleaning, condenser fan motor is not running or the compressor itself. Check the manufacturer's spec for what that exact resistance reading should be. For example it should read maybe 3 across one set (by set I mean 2 terminals), then 5 on another and 8 on the other set. Refrigerator Compressor | Refrigerator Troubleshooting Diagram testing-compressors: pin. The current drawn is about 17.6 amps, tag says max current is 6.5 amps. Carefully disconnect the wires with a pair of pliers, and then remove the relay by pulling it off of the prongs on the compressor. pin. Specifically, which 12 volt compressor fridge will give them the best cooling and last longest on their 12V leisure battery. I had a look at the data sheet of the compressor (NJ2212GK) and the resistance rating for the start winding is 7.25 ohms, the rated resistance value for the run winding is 1.95 ohms. Refrigerator Compressor Test. One of the many things that can make a refrigerator warm up is the compressor is trying but failing to start. I have done this on another refrigerator that had three terminals on the compressor, but this one is different. If the resistances vary from each other by as much as a 1 ohm, the compressor will not run correctly. SALTON FRIDGE DRAIN PAN. Shake n’ Tell for a Bad Compressor . There are no new entries! The refrigerator is about 1980 … (0:23) - STEP 2: Remove lower front panel from cooler. FITS MODELS: SF420BFSD, DBF380SD. How To Test the Compressor Motor. 5.0 (1) 3 Orders. Shake n’ Tell for a Bad Compressor . 5.0 out of 5 stars 3. Taking the time to learn how to test a refrigerator start relay can help you find any problems, fix them, and ultimately save you the money you'd have to spend on a new one. This is the main safety device for protection techniques from electric shock when the device is in the works and it protects the equipment from pressure from oil, if one of the terminal goes down and blow out her grief.   Access to training Check out the options listed here: Gorenje Refrigerators … Remember when removing the wires from the compressor, use a pair of insulated needle-nose pliers and keep your hands off to the side, not in front of the plug. refrigerator compressor ohm test. Hi guys, just to give an update. Here's the simple procedure I use whenever I run into one that’s ‘short-cycling’ (trying to start, clicking on/off every few seconds, or in some cases, every minute or two). If it’s tripped, you will read infinity (OL) between S to C and R to C, while seeing a measurable resistance between R to S. In this case, the compressor may be extremely hot to the touch. To test the sensor: – Measure the temperature of the sensor or the space the sensor is in. 0 0. Register in 3 easy steps, today! So long as you tested with your megger between any of the three compressor terminals (wires removed) with one test lead, and with the other test lead on a good earth and got a low reading (below 1 megger ohm (ish) it should be way above this) the the compressor has took a dirt nap. If you do not make adjustments with a little handle your counter to zero. With the relay removed from the compressor, the resistance between the start winding and common is 3 ohms, between motor winding and common is 9 ohms … Refrigerator Compressor | Refrigerator Troubleshooting Diagram amperage when terminating its defrost cycle and entering the freeze In fact, the compressor might trip its thermo-overload at that: pin. For example, 240 volt compressor can have a 120 volt condensation of the fan motor. With the service panel removed, look with your eyes, before you touch anything. Access to pricing and ordering US $2.44. If the compressor is shorted, you will need to recover the refrigerant anyway, so this gives you a head start on the compressor changeout. Dec 21, 2017 - (0:07) Ohm Testing a Compressor (0:12) - STEP 1: Remove (4) 5/16" lower panel screws. Product Sold Out. google_ad_client = "ca-pub-2749758595940365"; When this happens, the fault could be in the wiring, the control panel or the fan itself. Either memorize the wiring or take a few pictures just to be sure you know how to put it all back together when you're done. Meter for example, it can be purchased in the price range from $20 to $125, depending on the quality. If the compressor passes the above tests, take a multimeter set to R x 10,000 (10K) and check each winding to ground. For this reason, you should learn a systematic method of diagnostics compressor. If it doesn't, the refrigerator won't get cool enough to preserve your food. How to Troubleshoot Fridge Compressors. One of the many things that can make a refrigerator warm up is the compressor is trying but failing to start. Before you begin any work, ensure your work space is safe. This is a safety recommendation which must be followed when you are working with parts or equipment driven by electricity. If the compressor passes the above tests, take a multimeter set to R x 10,000 (10K) and check each winding to ground.        . New user coupon on orders over US $4.00. Then, use a multimeter to check the relay for open resistance. If the start relay is faulty in any way the compressor may fail to properly cycle cool air throughout your unit. use the OHM,s setting 2K a mid range or more reading is good . There's usually a diagram somewhere as well - make sure you can follow it and identify parts. Rang from the compressor; it means accepting continuity. It has two terminals leading to a capacitor (starter overlay) and also a red and white wire. Get shopping advice from experts, friends and the community! On LG refrigerators, the sensor should have a resistance 16 K-ohms ±5% at 32℉. Locked rotor. The main purpose of a start relay is to assist and provide additional torque to start the compressor. Allowing the compressor to cool down should reset the internal overload but you need to investigate further ensure the reset was indeed completed. Inc. “This will help avoid operational issues generated by improperly p… The wires must be removed from the compressor, to prevent tension from other circuits.

Aquest lloc web fa servir galetes per que tingueu la millor experiència d'usuari. Si continua navegant està donant el seu consentiment per a l'acceptació de les esmentades galetes i l'acceptació de la nostra política de cookies, premi l'enllaç per a més informació.

ACEPTAR
Aviso de cookies